Repository logo
  • English
  • Català
  • Čeština
  • Deutsch
  • Español
  • Français
  • Gàidhlig
  • Italiano
  • Latviešu
  • Magyar
  • Nederlands
  • Polski
  • Português
  • Português do Brasil
  • Srpski (lat)
  • Suomi
  • Svenska
  • Türkçe
  • Tiếng Việt
  • Қазақ
  • বাংলা
  • हिंदी
  • Ελληνικά
  • Српски
  • Yкраї́нська
  • Log In
    New user? Click here to register. Have you forgotten your password?
Repository logo
  • Communities & Collections
  • Browse UWCScholar
  • English
  • Català
  • Čeština
  • Deutsch
  • Español
  • Français
  • Gàidhlig
  • Italiano
  • Latviešu
  • Magyar
  • Nederlands
  • Polski
  • Português
  • Português do Brasil
  • Srpski (lat)
  • Suomi
  • Svenska
  • Türkçe
  • Tiếng Việt
  • Қазақ
  • বাংলা
  • हिंदी
  • Ελληνικά
  • Српски
  • Yкраї́нська
  • Log In
    New user? Click here to register. Have you forgotten your password?
  1. Home
  2. Browse by Author

Browsing by Author "Noordien, Naeemah"

Now showing 1 - 4 of 4
Results Per Page
Sort Options
  • Loading...
    Thumbnail Image
    Item
    Accuracy of Orthodontic bracket adaptation
    (University of the Western Cape, 2019) Noordien, Naeemah; Hudson, Athol
    Background: A close marginal adaptation between the tooth and the bracket base is important since it provides the space for the adhesive. In order to withstand and resist the orthodontic forces exerted as well as everyday forces like mastication and oral hygiene practices, the adhesive material to the bracket must have sufficient sheer bond strength. This means that no deformations, cracks, or fractures should occur within the bracket material and adhesive (Keizer et al., 1976). Aim: The aim of this study was to determine the accuracy of the marginal adaptation of the bracket bases of seven different brands of orthodontic brackets to the tooth surface of a right upper first premolar (ie. Abzil, Forestadent, GAC, Gemini, IMD, Ormco and Victory LP). Method: This research was an in vitro, descriptive comparison study. Fifteen caries and crack free intact human first premolars were used. The teeth were obtained from patients requiring extractions for orthodontic purposes and collected from Tygerberg Oral Health Centre. A convenience sample method was used, where whenever an upper caries free premolar was extracted, the parent was asked if the tooth could be used for this study and consent was obtained. The crowns of the 15 teeth were cleaned and polished with pumice and rubber cups for 10 seconds (as the clinician would do prior to bracket cementation). The same 15 teeth were used with the seven different brands of brackets in order to establish a comparison of the adaptability of the brackets. The brackets were placed at a set orthodontic prescription of 4mm (measured from the slot area of the bracket to the tip of the buccal cusp of the tooth) on the upper first premolars. After bracket placement, the dontrix gauge was applied to the bracket to engage the slot area. The brackets were held in place with a constant force of 0.70 Newton (N) by the dontrix gauge. This allowed for reproducibility for the seven brackets with all fifteen teeth. In order to assess the space between the brackets and the teeth no adhesive was used. The space between the margins of the bracket and tooth interface was viewed under the Stereomicroscope (Carl Zeiss microscope, Zeiss Stemi508) at 50 times magnification. A two way mixed measures ANOVA was run to determine whether there were differences between the seven brackets placed at six points on the tooth surface. Results: GAC had the smallest overall mean measurement between bracket base and tooth surface followed by Ormco and Gemini respectively. Abzil had the largest overall mean measurement for the six points around the bracket
  • Loading...
    Thumbnail Image
    Item
    Comparing cytocompatibility of two fluoride-containing solutions and two resin-based restorative materials—a pilot study
    (Frontiers Media SA, 2024) Mulder, Riaan; Noordien, Naeemah; Potgieter, Nicoline
    Background: Cytocompatibility should always be considered, especially if the surface of treated carious lesions is close to soft tissue or is accidentally exposed to the oral soft tissue by the clinician. Methods: The aim of the present study was to compare the cytocompatibility of two fluoride-containing liquids and two resin-containing restorative materials with buccal mucosa fibroblasts. The fluoride-containing materials were silver diamine fluoride and water-based silver fluoride. Results: The statistical analysis was completed by comparing the positive control growth of the buccal mucosa fibroblasts to the growth of cells exposed to various materials. The one-way ANOVA with Tukey’s HSD result was completed. All the assessed materials compared to the control wells for both the 24 and 48 h time intervals indicated a significant cytocompatibility result, except for the test wells with Stela (SDI) at the 24 h time interval. There was no significant difference between the step 2 liquids and the two dental materials in cytocompatibility at the 24 h interval. All four materials indicated no significant differences between the cytocompatibility of any dental materials for 48 h. Conclusion: The cytocompatibility assessment for Riva Star and Riva Star Aqua with the direct method in a full dispensing drop is not viable for step 1 of the fluoride-containing liquids. The use of Stela Light Cure is a suitable material that will be in contact with buccal mucosa as it showed potential for increased cytocompatibility compared to Riva Light Cure. Riva Star Aqua is more cytocompatible than Riva Star.
  • Loading...
    Thumbnail Image
    Item
    Extra-oral suction
    (MDPI, 2023) Noordien, Naeemah; Mulder-van Staden, Suné; Mulder, Riaan
    Oral health care workers (OHCW) are exposed to pathogenic microorganisms during dental aerosol-generating procedures. Technologies aimed at the reduction of aerosol, droplets and splatter are essential. This in vivo study assessed aerosol, droplet and splatter contamination in a simulated clinical scenario. The coolant of the high-speed air turbine was colored with red concentrate. The red aerosol, droplets and splatter contamination on the wrists of the OHCW and chests of the OHCW/volunteer protective gowns, were assessed and quantified in cm2 . The efficacy of various evacuation strategies was assessed: low-volume saliva ejector (LV) alone, high-volume evacuator (HV) plus LV and an extra-oral dental aerosol suction device (DASD) plus LV. The Kruskal– Wallis rank-sum test for multiple independent samples with a post-hoc test was used. No significant difference between the LV alone compared to the HV plus LV was demonstrated (p = 0.372059). The DASD combined with LV resulted in a 62% reduction of contamination of the OHCW. The HV plus LV reduced contamination by 53% compared to LV alone (p = 0.019945). The DASD demonstrated a 50% reduction in the contamination of the OHCWs wrists and a 30% reduction in chest contamination compared to HV plus LV. The DASD in conjunction with LV was more effective in reducing aerosol, droplets and splatter than HV plus LV.
  • Loading...
    Thumbnail Image
    Item
    In vitro analysis of techniques that alter the surface hardness of a glass ionomer restorative material
    (Jaypee Brothers Medical Publishers, 2019) Mulder, Riaan; Noordien, Naeemah; Rossouw, Shaun
    Ab s t r A c t Aim: The aim of this in vitro study was to compare the eect of dierent manipulation techniques on the surface hardness of ChemFil Rock glass ionomer.Materials and methods: The changes in Vickers surface hardness ( VH) of ChemFil Rock were evaluated after the application of ve manipulation techniques and compared with one control group (n = 60). The manipulation techniques included: nger pressure set, electronic piezo producing a high frequency set, air piezo producing a low frequency set, heat-set achieved with a curing light and the last technique was a combination of electronic piezo followed by heat-set. Standard set was the control.Results: The average surface hardness for the standard set was 49.5 VH. No statistical dierences were demonstrated when the means were compared for nger pressure set (49.2 VH) or the air piezo set (48.49 VH) with standard set. The electronic piezo (54.21 VH) and the heat-set (57.5 VH) had an increased mean surface hardness when compared to other techniques. Heat-set had the highest surface hardness demonstrating a signicant statistical dierence when compared with standard set, nger pressure set, air piezo set as well as the combination of electronic piezo (p < 0.05).Conclusion: The surface hardness of the glass ionomer cement (GIC) material assessed in this study can be predictably improved by applying the heat-set technique. A command set can be achieved with the electronic piezo or the air piezo, however, the surface hardness will only increase with the use of the electronic piezo.

DSpace software copyright © 2002-2025 LYRASIS

  • Cookie settings
  • Privacy policy
  • End User Agreement
  • Send Feedback