dc.description.abstractWe present a revised effective wavelength and photometric calibration for the Wide-field Infrared Survey Explorer W4 band, including tests of empirically motivated modifications to its pre-launch laboratory-measured relative system response curve. We derived these by comparing measured W4 photometry with photometry synthesised from spectra of galaxies and planetary nebulae. The difference between measured and synthesised photometry using the pre-launch laboratory-measuredW4 relative system response can be as large as 0.3 mag for galaxies and 1 mag for planetary nebulae. We find theW4 effective wavelength should be revised upward by 3.3%, from 22.1 to 22.8 μm, and theW4 AB magnitude of Vega should be revised from mW4 = 6.59 to mW4 = 6.66. In an attempt to reproduce the observedW4 photometry, we tested three modifications to the pre-launch laboratory-measured W4 relative system response curve, all of which have an effective wavelength of 22.8 μm. Of the three relative system response curve models tested, a model that matches the laboratory-measured relative system response curve, but has the wavelengths increased by 3.3% (or 0.73 μm) achieves reasonable agreement between the measured and synthesised photometry.en_US
dc.identifier.citationBrown, M. J. I., Jarrett, T. H., & Cluver, M. E. (2014). Recalibrating the wide-field infrared survey explorer (WISE) W4 filter. Publications of the Astronomical Society of Australia, 31 doi:10.1017/pasa.2014.44en_US
dc.identifier.issnhttps//doi.org:/10.1017/pasa.2014.44
dc.identifier.urihttp://hdl.handle.net/10566/8533
dc.language.isoenen_US
dc.publisherCambridge University Pressen_US
dc.subjectGalaxies: photometryen_US
dc.subjectGalaxies: Infrareden_US
dc.subjectPlanetary nebulae: generalen_US
dc.titleRecalibrating the Wide-field Infrared Survey Explorer (WISE) W4 Filteren_US
dc.typeArticleen_US

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
brown_Recalibrating-the-Widefield-Infrared-Survey-Explorer-_2023.pdf
Size:
259.52 KB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: