In vitro analysis of the marginal adaptation and discrepancy of stainless steel crowns

dc.contributor.authorMulder, Riaan
dc.contributor.authorMedhat, Rasha
dc.contributor.authorMohamed, Nadia
dc.date.accessioned2019-10-29T14:14:40Z
dc.date.available2019-10-29T14:14:40Z
dc.date.issued2018
dc.description.abstractAim: The purpose of the study was to assess the marginal adaptation and discrepancy of SSC’s. Differences in adaptation and discrepancy between the four surfaces (mesial, lingual, distal, and buccal) were evaluated. Methods: The placement of stainless steel crowns were completed on a phantom head in accordance with the clinical technique. The ideal tooth preparation was made and this ‘master tooth’ duplicated to achieve a sample size of 15. The stainless steel crowns were placed, trimmed, and cemented as per the clinical technique. The cemented stainless crowns were analyzed under 100 stereomicroscope magnification. The marginal adaptation and discrepancy of each specimen was measured every 2 mm. Results: All the specimens showed marginal adaptation and discrepancy. The lingual margin had a significantly better adaptation (p<.0001) over the other surfaces. The buccal surface was the only surface that had an appropriate supra-CEJ level with a significance of p<.0001. Conclusion: The marginal discrepancies occur during the trimming procedure and assessment of the gingival approximation of the SSC margin. The inspection of stainless steel crown adaptation and discrepancy is an essential clinical step.en_US
dc.identifier.citationRiaan Mulder, Rasha Medhat & Nadia Mohamed (2018) In￿vitro analysis of the marginal adaptation and discrepancy of stainless steel crowns, Acta Biomaterialia Odontologica Scandinavica, 4:1, 20-29, DOI: 10.1080/23337931.2018.1444995en_US
dc.identifier.issn2333-7931
dc.identifier.urihttps://doi.org/10.1080/23337931.2018.1444995
dc.identifier.urihttp://hdl.handle.net/10566/5078
dc.language.isoenen_US
dc.publisherTaylor & Francisen_US
dc.subjectBiomaterial cementen_US
dc.subjectStainless steel crownen_US
dc.subjectGingival approximationen_US
dc.subjectCrown marginen_US
dc.titleIn vitro analysis of the marginal adaptation and discrepancy of stainless steel crownsen_US
dc.typeArticleen_US

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
In vitro analysis of the marginal adaptation and discrepancy of stainless steel crowns.pdf
Size:
2.39 MB
Format:
Adobe Portable Document Format
Description:
mulder_stainless_steel_crowns_2018
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: